Project Data Sheet
| ||||
| ||||
| Passive House Days Attendance: | '07 '08 | |||
| Building type: | detached single family house (Passive House new build) | |||
| Project description: | - 1. Passivhaus in Metallständerbauweise
- Berechnung mit PHPP | |||
| Location: | D-15890 Eisenhüttenstadt (Brandenburg) | |||
| Number of apartments / units: | 1 | |||
| Treated Floor Area according to PHPP: | 136 m² | |||
| Construction type: | mixed construction (timber and masonry) | |||
| Exterior wall: | Dicke: 0,440 m
15 mm Fermacell, 150 mm Mineralfaser, 15 mm Fermacell, 260 mm Purenotherm U-value = 0,09 W/(m²K) | |||
| Basement floor / floor slab: | Dicke: 0,450 m
200 mm Beton 250 mm Dämmung U-value = 0,153 W/(m²K) | |||
| Roof: | Dicke: 0,373 m
13 mm Fermacell, 200 mm Mineralfaser, Stahl, 160 mm Purenotherm U-value = 0,095 W/(m²K) | |||
| Frame: | Rehau, Clima Design ![]() Uw-value = 0,71 W/(m²K) | |||
| Glazing: | Unitop 0.51-52 - UNIGLAS ![]() g-value = 52 % | |||
| Entrance door: | Ud-value = 0,8 W/(m²K) | |||
| Ventilation: | Sachsenland Bauelemente GmbH, Innoair 255 DC ![]() Lüftungsanlage mit Wärmerückgewinnung superleise Ventilatoren, niedrigste Energieverbräuche, Wirkungsgrad von 88 bis 99%, vollautomatischer Balanceausgleich zwischen Zu- und Abluft Sole-Erdwärmetauscher zur Vorwärmung der Außenluft im Winter (von -15°C auf +2°C) und Kühlung der Zuluft im Sommer (von 30°C auf ca. 18°C), automatische Verschattung durch Außenraffstores | |||
| Heating installation: | Passivhaus-Kleinst-Kompakt-Erdwärmepumpe
INNO-SWP 40 monovalente Auslegung, 3,3 kW Heizleistung, Speichergröße vermeidet unnötige Wärmeübertragung im Sommer an Bauteile und Lüftungskanäle, Anbindung mittels PE-Xa-Sonde (1x50m Tiefe) oder mit 2 Flächenkollektoren (je 70m lang) | |||
| Domestic hot water: | Passivhaus-Kleinst-Kompakt-Erdwärmepumpe
INNO-SWP 40 | |||
| Air tightness: | n50 = 0,6/h | |||
| Ecological aspects: | ||||
| Annual heating demand: | 15 kWh/(m²a) calculated according to PHPP | |||
| Heating load: | 8 W/(m²) calculated according to PHPP | |||
| Primary energy requirement: | 100 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP | |||
| Construction costs (gross): | ||||
| Building structure costs (gross): | ||||
| Year of construction: | 2005 | |||
| Architecture: | Jens Ruhla | |||
| Building services: | ||||
| Building physics: | ||||
| Statics: | ||||
| Craftsperson / parties involved: | ||||
| Miscellaneous: | ||||
| Other parties involved: | Sachsenland Bauelemente GmbH | 08393 Meerane | Lüftungstechnik ![]() | |||
Project database www.passivehouse-buildings.org | Last change: 24.02.2011