Project Data Sheet
| ||||
| Passive House Days Attendance: | '04 | |||
| Building type: | detached single family house (Passive House new build) | |||
| Project description: | ||||
| Location: | D-54317 Lorscheid (Rheinland-Pfalz) | |||
| Number of apartments / units: | 1 | |||
| Treated Floor Area according to PHPP: | 158 m² | |||
| Construction type: | insulated concrete forms | |||
| Exterior wall: | Wolf-Thermomodul Betonschalungsstein 43,75 cm U-value = 0,114 W/(m²K) | |||
| Basement floor / floor slab: | Thermobodenplatte 30 cm WLG 035, 25 cm Beton U-value = 0,1 W/(m²K) | |||
| Roof: | TJI-Dachkonstruktion 406 mm mit Zellulosedämmung U-value = 0,1 W/(m²K) | |||
| Frame: | Wiegand DW-plus Uf-Wert = 0,80 W/(m²K) | |||
| Glazing: | Ug-value = 0,6 W/(m²K) g-value = 55 % | |||
| Entrance door: | ||||
| Ventilation: | EnEV Air LWDC425-SBR/L EWT aus HDPE-Rohr | |||
| Heating installation: | PTC-Elemente am Zuluftventil dezentral | |||
| Domestic hot water: | Boilerwärmepumpe 290 Liter mit Erdabsorber | |||
| Air tightness: | n50 = 0,25/h | |||
| Ecological aspects: | ||||
| Annual heating demand: | 15 kWh/(m²a) calculated according to PHPP | |||
| Heating load: | ||||
| Primary energy requirement: | 115 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP | |||
| Construction costs (gross): | ||||
| Building structure costs (gross): | ||||
| Year of construction: | 2004 | |||
| Architecture: | passiv 21 GmbH | |||
| Building services: | Markus Paulus | |||
| Building physics: | ||||
| Statics: | ||||
| Craftsperson / parties involved: | ||||
| Miscellaneous: | ||||
| Other parties involved: | Wiegand Fensterbau | 35116 Hatzfeld-Holzhausen | Fensterbau | |||
Project database www.passivehouse-buildings.org | Last change: 24.02.2011