Passive House Buildings

deutsch english

Project Data Sheet

< Back to Overview | Print Project Data Sheet >
 

D-54636 Fliessem (Rheinland-Pfalz)

     

Project ID: 0423

 
 D-54636 Fliessem (Rheinland-Pfalz)  
Building type:detached single family house (Passive House new build) 
Project description:Einfamilienhaus in Holzrahmenbauweise 
Location:D-54636 Fliessem (Rheinland-Pfalz) 
Number of apartments / units: 
Treated Floor Area according to PHPP:167 m² 
Construction type:timber construction 
Exterior wall:Holzrahmen, 6 / 20 cm + 2 x 6 / 8 cm, Mineralwolle 36 cm / WLG 035
U-value = 0,133 W/(m²K) 
Basement floor / floor slab:Kriech-Kellerdecke: Holzbalken, 6 / 24 cm, e = 62,5 cm, Mineralfaser 24 cm / 035 + 16 cm / WLG 040
U-value = 0,144 W/(m²K) 
Roof:Pultdach, Sparren 24 cm + 12 cm, Mineralfaser WLG 035
U-value = 0,118 W/(m²K) 
Frame:
Kunststoff Internorm
Uw-value = 0,78 W/(m²K) 
Glazing:

Ug-value = 0,6 W/(m²K)
g-value = 56 % 
Entrance door:
 
Ventilation:
Erdwärmetauscher, 50 m Länge, AEREX-Kompaktgerät 
Heating installation:Wärmerückgewinnung und Kleinstwärmepumpe (AEREX), Nachheizung direktelektrisch 
Domestic hot water:Erwärmung über AEREX-Kompaktgerät 
Air tightness:n50 = 0,51/h 
Ecological aspects:Holz als Baustoff im Allgemeinen; Selbstbauhaus aus eigenem Holz, maximale Eigenleistung nach Werkstattplänen IB H&L  
Annual heating demand:14 kWh/(m²a) calculated according to PHPP 
Heating load: 
Primary energy requirement:120 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP 
Construction costs (gross): 
Building structure costs (gross): 
Year of construction:2002 
Architecture:Planungsbüro Schenten (HOAI 1-4) + Herz&Lang GmbH 
Building services:Herz&Lang GmbH 
Building physics:Herz&Lang GmbH 
Statics:Herz&Lang GmbH 
Craftsperson / parties involved:Fachplaner Bautechnik: Herz&Lang GmbH 
Miscellaneous: 
Other parties involved:Herz & Lang GmbH | 87480 Weitnau / Oberallgäu    Member IG Passivhaus Deutschland    Certified Passive House Designer

Project database www.passivehouse-buildings.org | Last change: 19.12.2011