E-25198 Lleida (Cataluņa) | | Project ID: 2116 |
|
| |
| | |
| Passive House Days Attendance: | '11 '12 |
| Building type: | terraced house (low energy new build with PH components) |
| Project description: | Prefabricated wood, local sheep's wool insulation and wood fibre. Construction price less than 1100/m2. Build time, 6 months. Energy consumption heating 10kwh/m2 year PHPP. Minimum gray energy of materials. Positive CO2 balance. Minimized ecological footprint. Adapted to the European guidelines for low consumption 2012-2020. With 6m2 of PV power generation could be a ZEB (Zero Emission Building). Annual heating cost, 250. Removable. |
| Location: | E-25198 Lleida (Cataluņa) |
| Number of apartments / units: | 1 |
| Treated Floor Area according to PHPP: | 176 m² |
| Construction type: | timber construction |
| Exterior wall: | Ventilated wood 25mm
Wood fibre (045), 22mm
Wood structure and insulation (041), 160mm
Osb 15mm
average
U-value = 0,215 W/(m²K) |
| Basement floor / floor slab: | concret, 160mm
polyestiren insulation (040), 100mm U-value = 0,35 W/(m²K) |
| Roof: | Ventilated cladding 1mm
Wood fibre (045), 22mm
Wood structure and insulation (041), 260mm
Osb 15mm
average U-value = 0,147 W/(m²K) |
| Frame: | n.n., n.n. wooden windows (68mm), partly fixed glazing,
parts in post and beam construction
Editor's note: For a very good thermal protection and full comfort in passive houses Uf-/ Uw- values should consider the specific climate data. Uw-value = 1,65 W/(m²K) |
| Glazing: | double glazing - due to the climate, 4-14-4 / low e, argon
Editor's note: For a very good thermal protection and full comfort in passive houses Ug / g - values should consider the specific climate data.
Ug-value = 1,2 W/(m²K) g-value = 65 % |
| Entrance door: | insulated wooden door
Ud-value = 1,8 W/(m²K) |
| Ventilation: | mitsubishi, LGH-15RX4-E specific efficiency 58% |
| Heating installation: | underfloor space heating, condensing boiler gas and solar collectors 6mē |
| Domestic hot water: | condensing boiler gas and solar collectors 6mē,
circulation and individual pipes |
| Air tightness: | n50 = 1/h |
| Ecological aspects: | rain water harvesting to garden and wc
local sheep wool insulation and local wood structure to the pyrenees |
| Annual heating demand: | 7 kWh/(m²a) calculated according to PHPP |
| Heating load: | 13 W/(m²) calculated according to PHPP |
| Primary energy requirement: | 52 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP |
| Construction costs (gross): | 1100 €/m² Treated Floor Area according to PHPP (costs include site development, construction, building services, appurtenant structures, additional costs) |
| Building structure costs (gross): | 450 €/m² total demand (costs only include the construction and the building services) |
| Year of construction: | 2009 |
| Architecture: | josep bunyesc |
| Building services: | josep bunyesc |
| Building physics: | josep bunyesc |
| Statics: | josep bunyesc |
| Craftsperson / parties involved: | |
| Miscellaneous: | Editor's note: To define a building as a passive house, the criteria for the heating demand, the primary energy and the building airtightness are to be observed.
Editor's note: The verification considers local climate data.
In Central European Climate the U-values of opaque building elements are recommended to be less than 0,15 W/(mēK). In case of deviating climate conditions this may require review, U-values are always linked to specific climate data. Thermal bridges should be considered.
|