Building type:detached single family house (Passive House new build) 
Project description:Einfamilienhaus in Holzbauweise mit Putzfassade, gedämmter Keller in Stahlbeton.  
Location:D-82256 Fürstenfeldbruck (Bayern) 
Number of apartments / units: 
Treated Floor Area according to PHPP:215 m² 
Construction type:timber construction 
Exterior wall:Putz 10 mm, Holzweichfaserplatte 60 mm, Steico-Träger/ Zellulose-Dämmung 300 mm, OSB-Platte 15 mm, Dämmung 60 mm, Gipskarton 15 mm


U-value = 0,1 W/(m²K) 
Basement floor / floor slab:Estrich 50 mm, Dämmung 180 mm, Stahlbeton 250 mm, Perimeterdämmung 120 mm Sauberkeitsschicht 50 mm


U-value = 0,12 W/(m²K) 
Roof:Ziegel-Deckung 35 mm, Lattung 60 mm, Lattung 50 mm, DWD-Platte 16 mm, Steico-Träger/ Zellulose-Dämmung 300 mm, OSB-Platte 15 mm


U-value = 0,12 W/(m²K) 
Frame:Variotec, Energyframe PHI-certified frame

Uw-value = 0,73 W/(m²K) 
Glazing:Hersteller: Glas Trösch AG, Argonfüllung
Amberger Isolierglas, Produkt Sanco Solar


Ug-value = 0,6 W/(m²K)
g-value = 52 % 
Entrance door:Profil Variotec

PHI-certified entrance door

Ud-value = 0,69 W/(m²K) 
Ventilation:Paul, Atmos 175 PHI-certified ventilation appliance
Lüftungsanlage mit Wärmetauscher Vortemperierung mit Erdwärmerohr

 
Heating installation:Holzscheitkessel mit Warmwasserwärmtauscher 
Domestic hot water:wie Heizung, + Solarkollektor, Flachkollektor 14 qm, Solarschichtenspeicher 1000 l 
Air tightness:n50 = 0,33/h 
Ecological aspects:Baustoff Holz , Zellulose-Dämmung, regenerative Energien, Photovoltaikanlage 
Annual heating demand:14 kWh/(m²a) calculated according to PHPP 
Heating load:13 W/(m²) calculated according to PHPP 
Primary energy requirement:67 kWh/(m²a) total demand on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP 
Construction costs (gross):2000 €/m² Treated Floor Area according to PHPP (costs include site development, construction, building services, appurtenant structures, additional costs) 
Building structure costs (gross):1807 €/m² total demand (costs only include the construction and the building services) 
Year of construction:2007 
Architecture:Architekturbüro Vallentin 
Building services:Ingenieurbüro Lackenbauer 
Building physics: 
Statics:Ingenieurbüro Jochum 
Craftsperson / parties involved: 
Miscellaneous: 
Other parties involved:Architekturbüro Vallentin | 84405 Dorfen | Planung der Architektur     Member IG Passivhaus Deutschland    Certified Passive House Designer

Project database www.passivehouse-buildings.org | Last change: 24.02.2011